Product Description:
POLYCIMA-105XLF is a flame-retardant cross-linked material based primarily on an aluminum-magnesium flame retardant system. This product offers excellent mechanical and physical properties, electrical performance, and processing characteristics, and complies with environmental regulations such as ROHS, SVHC, 16P, and PAHS.
Product Applications:
This product complies with UL758 standards and is suitable for UL105°C rated electronic wires, UL10368, 3302, 3385, 3386 series wires, as well as flat cable UL4478 and other products. It passes the single horizontal flame test.
Performance | Test Method | Unit | Typical Value |
Density | ISO 1183 | g/cm³ | 1.28 |
Tensile Strength | IEC60811-1-1 | MPa | 20 |
Elongation at Break | IEC60811-1-1 | % | 420 |
Aging Performance | IEC60811-1-2 | °C × h | 136°C × 168 |
Tensile Strength Retention | IEC60811-1-2 | % | ≥75 |
Elongation at Break Retention | IEC60811-1-2 | % | ≥75 |
Low Temperature Brittleness Temperature | GB/T5470 | °C | -40 |
Toxicity Index |
|
| 1.0 |
pH Value | IEC60754-2 |
| 5.0 |
Electrical Conductivity |
| μs/mm | 0.48 |
Dielectric Strength | GB/T1408 | KV/mm | 25 |
Oxygen Index | ISO4589-2 | % | 32 |
Packaging/Storage:
25 kg/bag. Transport as general chemical product. Store in a dry, cool place away from direct sunlight. Shelf life: 1 year.
Note:
The technical property indicators and data provided in this document are for reference only and cannot be used as a basis for inspection or guarantee. Users who purchase our products are also responsible for conducting their own tests to verify whether the product is suitable for their intended processes, applications, performance requirements, and standards. Since the application and processing of our products are beyond our control, any related issues shall be solely the responsibility of the user.

Processing Precautions:
A: It is recommended to dry the material at 90°C for 2–4 hours.
B: It is recommended to clean the screw or die head with polypropylene (PP) or polyethylene (PE) before and after processing this material.
C: Trim scrap can be reused. It must be dried before use, and the addition amount should generally not exceed 15%. The performance is basically unaffected.